24SepCelebrating The Mid-Autumn Festival: Leadtek Shares The Warmth Of Tradition W...As the full moon rises and the sweet scent of mooncakes fills the air, ZHEJIANG LEADTEK FLUID TECHNOLOGY CO., LTD is delighted to extend its warmes...
view more
23SepStainless Steel Check Valve Selection Guide For Battery Formation & Grading S...Introduction: A Hidden Cause of Cell Inconsistency That Most Engineers Overlook In lithium-ion battery manufacturing, formation and grading is the ...
view more
16Sep3 PC Ball Valve In Lithium Battery Electrolyte Transfer: Why Full-Port Design...The Problem Nobody Talks About Until Something Goes Wrong A production engineer at a lithium-ion cell facility once described the moment they reali...
view more
10SepPipe Fittings For Coolant Distribution Units (CDUs): A Buyer's GuideMost procurement mistakes in CDU cooling projects don't happen at the pump or heat exchanger level. They happen at the fittings - the elbow nob...
view more
02SepImmersion Cooling Vs. Direct-To-Chip Cooling: What It Means For Your Piping S...Introduction: The Decision That Happens Too Late Most data center engineers make their cooling technology choice - immersion or direct-to-chip - ba...
view more
26AugWhy Stainless Steel Ball Valves Are Replacing Brass In Coolant Distribution U...Introduction: Why the Right Ball Valve Matters in CDU Liquid Cooling Systems As artificial intelligence (AI), high-performance computing (HPC), and...
view more
21AugCamlock Fittings For Liquid Cooling Quick Disconnect Applications: A Practica...Introduction: Why Choosing the Right Quick Connection Matters in Liquid Cooling Systems As liquid cooling systems become more common in data center...
view more
13AugCorrosion Resistance In Liquid Cooling Systems: Why Stainless Steel Outperfor...Introduction: The Hidden Threat Inside Your Cooling Loop A data center operator in Germany noticed something troubling six months after commissioni...
view more
06AugStainless Steel Tees And Reducers For Liquid Cooling Manifolds: A Practical S...1. Introduction: The Hidden Cost of the Wrong Fitting Picture this: a newly commissioned data center Direct-to-Chip (D2C) cooling loop - a system w...
view more
30JulBall Valves in Direct-to-Chip Liquid Cooling: Flow Control Requirements Expla...When a data center engineer specifies cooling equipment for a 100 kW GPU rack, the conversation usually starts with cold plates, CDUs, and manifold...
view more
23JulBeyond The Classroom, Into The Factory: Leadtek Opens Its Doors To The Next G...QUZHOU, Zhejiang, China - July 21, 2025 On the morning of July 21, approximately 45 students from local polytechnic and technical schools visited Z...
view more
12JulHow Thread Butterfly Valves Are Reshaping Data Center Cooling InfrastructureData centers are no longer the quiet, air-conditioned server rooms of the early 2000s. Today, a single hyperscale facility can draw 50 to 200 megaw...
view more